900180014
Power supply has lost redundancy.
Description
One or more power supplies in a redundancy set are experiencing the following issues:
The power supply unit is incorrectly seated.
The power cable may be improperly connected, or disconnected.
The power supply unit has failed.
There is an input power failure.
Administrator action
Inspect the specified redundant power supply set and restore redundancy.
900180015
System {desc} sensors have detected degraded or unhealthy components that may require maintenance. Sensors: {sensor_list}.
Description
The event is generic for groups of sensor types. It is useful for voltage and amperage sensors. Only one event of this type is
created per node. Only the most current list of specific sensors that are affected is listed to reduce the number of events per
cluster.
Administrator action
For the affected sensors, see the Event and Error Message Reference Guide.
900180016
System {desc} sensors are unhealthy and may require maintenance. Sensors: {sensor_list}.
Description
A sensor is damaged, or is unhealthy.
Administrator action
Replace the sensors provided in the list of damaged sensors.
Hardware events
197

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerScale OneFS and is the answer not in the manual?

Dell PowerScale OneFS Specifications

General IconGeneral
BrandDell
ModelPowerScale OneFS
CategoryStorage
LanguageEnglish

Related product manuals