DVP15MC11T Operation Manual
_8
The data types of variables SUB_In1, SUB _In2 and Out1 are all TIME and the values of SUB _In1
and SUB _In2 are TIME#4s and TIME#1s respectively. The value of Out1 is TIME#3s when
SUB_EN changes to TRUE as shown in Variable 2.
The data types of variables SUB_In1, SUB _In2 and Out1 are DATE, DATE and TIME and the
values of SUB _In1 and SUB _In2 are DATE#2016-10-1 and DATE#2016-9-1 respectively. The
value of Out1 is TIME#30D when SUB_EN changes to TRUE as shown in Variable 3.
Variable 1
Variable name
Data type
Current value
SUB_EN
BOOL
TRUE
SUB _In1
INT
100
SUB _In2
INT
40
Out1
INT
60
Variable 2
Variable name Data type Current value
SUB_EN
BOOL
TRUE
SUB_In1
TIME
TIME#4s
SUB_In2
TIME
TIME#1s
Out1
TIME
TIME#3s
Variable 3
Variable name
Data type
Current value
SUB_EN
BOOL
TRUE
SUB_In1
DATE
DATE#2016-10-1
SUB_In2
DATE
DATE#2016-9-1
Out1
TIME
TIME#30D
The program
1
SUB
EN ENO
In1 Out
In2
SUB_EN
SUB_In1
SUB_In2
Out1
8-58