DVP15MC11T Operation Manual
_8
8.9 Bit String Instructions
8.9.1 AND
FB/FC
Explanation
Applicable
model
FC
AND is used for performing a logical AND operation of two or more variables or
constants.
DVP15MC11T
Parameters
Parameter
name
Meaning
Input/
Output
Description Valid range
In1 to InN Operands Input
The number of operands can be
increased or decreased through the
programming software. Maximum: 8.
Minimum: 2. That is N=2 ~ 8.
Depends on the data type
of the variable that the
input parameter is
connected to.
Out
Operation
result
Output AND operation result of In1 ~ InN
Depends on the data type
of the variable that the
output parameter is
connected to.
Boolean
Bit string Integer
Real
number
Time, date
String
BOOL
BYTE
WORD
DWORD
LWORD
USINT
UINT
UDINT
ULINT
SINT
INT
DINT
LINT
REAL
LREAL
TIME
DATE
TOD
DT
STRING
In1
to
InN
Out
Note:
The symbol indicates that the parameter is allowed to connect to the variable or constant of the data type.
Function Explanation
AND is used for performing a bitwise logical AND operation of two or more variables or constants
and the result is output to Out. That is Out = In1 & In2 &
& InN
The operational rule:
The corresponding bit of the output variable is TRUE when corresponding bits of input variables are
all TRUE as shown below. Otherwise, the corresponding bit of the output variable is FALSE.
AND
EN ENO
In1 Out
InN
.
.
.
.
..
8-110

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics DVP15MC11T and is the answer not in the manual?

Delta Electronics DVP15MC11T Specifications

General IconGeneral
BrandDelta Electronics
ModelDVP15MC11T
CategoryController
LanguageEnglish

Related product manuals