_8
Programming Example
The data types of variables MODREAL _In1, MODREAL _In2 and Out1 are REAL, REAL and
LREAL respectively. The values of MODREAL _In1 and MOD _In2 are 10.5 and 2.5 respectively.
The value of Out1 is 0.5 when MODREAL _EN changes to TRUE.
The variable table and program
Variable name
Data type
Current value
MODREAL_EN
BOOL
TRUE
MODREAL _In1
REAL
10.5
MODREAL _In2
REAL
2.5
Out1
LREAL
0.5
1
MODREAL
EN ENO
In1 Out
In2
MODREAL_EN
MODREAL_In1
MODREAL_In2
Out1