EasyManuals Logo

Delta Electronics DVP15MC11T User Manual

Delta Electronics DVP15MC11T
601 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #139 background imageLoading...
Page #139 background image
DVP15MC11T Operation Manual
_8
Programming Example
The data types of variables MODREAL _In1, MODREAL _In2 and Out1 are REAL, REAL and
LREAL respectively. The values of MODREAL _In1 and MOD _In2 are 10.5 and 2.5 respectively.
The value of Out1 is 0.5 when MODREAL _EN changes to TRUE.
The variable table and program
Variable name
Data type
Current value
MODREAL_EN
BOOL
TRUE
MODREAL _In1
REAL
10.5
MODREAL _In2
REAL
2.5
Out1
LREAL
0.5
1
MODREAL
EN ENO
In1 Out
In2
MODREAL_EN
MODREAL_In1
MODREAL_In2
Out1
8-68

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics DVP15MC11T and is the answer not in the manual?

Delta Electronics DVP15MC11T Specifications

General IconGeneral
BrandDelta Electronics
ModelDVP15MC11T
CategoryController
LanguageEnglish

Related product manuals