EasyManua.ls Logo

Delta Electronics DVP15MC11T

Delta Electronics DVP15MC11T
601 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DVP15MC11T Operation Manual
_8
Data type
The value of In corresponds to the value of Out
In
Out
In
Out
DINT
16#****_8000~16#****_FFFF
-32768~-1
DINT
16#0000_0000~16#7FFF_FFFF
0~2147483647
16#8000_0000~16#FFFF_FFFF
-2147483648~-1
LINT
16#0000_0000~16#FFFF_FFFF
0~4294967295
LINT
USINT
16#****_****_****_**00~
16#****_****_****_**FF
0~255
UINT
16#****_****_****_0000~
16#****_****_****_FFFF
0~65535
UDINT
16#****_****_0000_0000~
16#****_****_FFFF_FFFF
0~4294967295
ULINT
16#0000_0000_0000_0000~
16# FFFF_FFFF_FFFF_FFFF
0~18446744073709551645
SINT
16#****_****_****_**00~
16#****_****_****_**7F
0~127
16#****_****_****_**80~
16#****_****_****_**FF
-
128~-1
INT
16#****_****_****_0000~
16#****_****_****_7FFF
0~32767
16#****_****_****_8000~
16#****_****_****_FFFF
-
32768~-1
DINT
16#****_****_0000_0000~
16#****_****_7FFF_FFFF
0~2147483647
16#****_****_8000_0000~
16#****_****_FFFF_FFFF
-
2147483648~-1
LINT
16#0000_0000_0000_0000~
16#7FFF_FFFF_FFFF_FFFF
0~9223372036854775807
16#8000_0000_0000_0000~
16#FFFF_FFFF_FFFF_FFFF
-
9223372036854775808~0
Integer to Real number
The Integer data can be converted to the Real-number data. And some instructions are shown
below.
SINT_TO_REAL
EN ENO
OutIn
INT_TO_LREAL
EN ENO
OutIn
USINT_TO_REAL
EN ENO
Out
In
UINT_TO_LREAL
EN ENO
Out
In