ASDA A2-E Chapter 8 Alarm List
8-4 Revision April, 2015
8.2 Error Code Table
Display Description
32bit-ErrorCode
(16bit-ErrorCode +
16bit-Additional Info)
AL001 Overcurrent 2310-0001
h
AL002 Overvoltage 3110-0002
h
AL003 Undervoltage 3120-0003
h
AL004 Motor error 7122-0004
h
AL005 Regeneration error 3210-0005
h
AL006 Overload 3230-0006
h
AL007 Overspeed 8400-0007
h
AL008 Abnormal pulse control command 8600-0008
h
AL009 Excessive deviation 8611-0009
h
AL010 Reserved 0000-0010
h
AL011 Encoder error 7305-0011
h
AL012 Adjustment error 6320-0012
h
AL013 Emergency stop activated 5441-0013
h
AL014 Reverse limit switch error 5443-0014
h
AL015 Forward limit switch error 5442-0015
h
AL016 IGBT temperature error 4210-0016
h
AL017 Memory error 5330-0017
h
AL018 Encoder output error 7306-0018
h
AL019 Serial communication error 7510-0019
h
AL020 Serial communication time out 7520-0020
h
AL021 Reserved Reserved
AL022 Input power phase loss 3130-0022
h
AL023 Early warning for overload 3231-0023
h
AL024 Encoder initial magnetic field error 7305-0024
h
AL025 Encoder internal error 7305-0025
h
AL026 Encoder internal error 7305-0026
h
AL027 Encoder data error 7305-0027
h