EasyManua.ls Logo

Delta ASDA-B2 Series - Page 140

Delta ASDA-B2 Series
345 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASDA-B2 Chapter 6 Control Modes of Operation
Revision May, 2018 6-29
P2-43 NCF2 Resonance Suppression (Notch Filter) 2
Address: 0256H
0257H
Operation
Interface:
Panel/Software Communication
Related Section:
Section 6.3.7
Default: 1000
Control
Mode:
ALL
Unit: Hz
Range: 50 ~ 2000
Data Size: 16-bit
Display
Format:
Decimal
Settings: The second setting value of resonance frequency. If P2-44 is set
to 0, this function is disabled. P2-23 and P2-24 are the first Notch
filter.
P2-44 DPH2
Resonance Suppression (Notch Filter)
Attenuation Rate (2)
Address: 0258H
0259H
Operation
Interface:
Panel/Software Communication
Related Section:
Section 6.3.7
Default: 0
Control
Mode:
ALL
Unit: dB (0: Disable the function of notch filter)
Range: 0 ~ 32
Data Size: 16-bit
Display
Format:
Decimal
Settings: The second resonance suppression (notch filter) attenuation
rate. When this parameter is set to 0, the function of Notch filter
is disabled.

Table of Contents