ASDA-B2 Chapter 7 Parameters
Revision May, 2018 7-95
P4-23
TAO Analog Torque Input Offset
Address: 042EH
042FH
Operation
Interface:
Panel / Software Communication
Related Section: N/A
Default: 0
Control
Mode:
T
Unit: mV
Range: -5000 ~ 5000
Data Size: 16-bit
Format: Decimal
Settings: Users manually adjust the offset
P4-24
LVL Level of Undervoltage Error
Address: 0430H
0431H
Operation
Interface:
Panel / Software Communication
Related Section: N/A
Default: 160
Control
Mode:
ALL
Unit: V (rms)
Range: 140 ~ 190
Data Size: 16-bit
Format: Decimal
Settings: When the voltage of DC BUS is lower than P4-24*
2
, the under
voltage alarm occurs.