DVP-ES3/EX3/SV3/SX3 Series Hardware and Operation Manual
9-34
9.4.6.2 Consumed TAG
The way to create a consumed TAG is the same the way to create a Produced TAG. Refer the section above for more
information. After the setups are complete, download the parameters to the PLC, even if using one’s own EIP data
mapping table.
9.4.6.3 Use TAG to Execute Data Mapping
You can enter the IP address to be connected to other TAGs so that creating a General Device is not necessary.
Once you select the TAG check box, the directional arrow is to the left with () (READ only)
1. Enter the IP address of the TAG device to be connected
2. Select the created Consumed TAG from the CPU register address /TAG column.
After you select the TAG, the software shows the same TAG name in the register address / parameters / address for the
Adapter. You can modify the TAG name to have the same name as the Produced TAG name.
3. Set the properties
4. Click the Downloader button on the tool bar to open the Project Downloader window.