GAVIN-8C Instruction Manual
- 40 -
set the swash type.
Values:
1 Servo: Each channel controls one servo, each servo controls one kind of
operation, without mixing. If the Type is set to 1 Servo, do not need to set
the mixing rate in step 3.
120°: This swash type is shown in the following figure. After selecting this
swash type, you can adjust the swash mixing by setting the mixing rate in
step 3.
140°: This swash type is shown in the following figure. After selecting this
swash type, you can adjust the swash mixing by setting the mixing rate in
step 3.
90°: This swash type is shown in the following figure. After selecting this
swash type, you can adjust the swash mixing by setting the mixing rate in
step 3.
The default is 1 Servo.
O (B)
A
C D
Elevator Servo
Aileron Servo Pitch Servo
90°
90° CCPM
O
A
BC D
Elevator Servo
Aileron Servo Pitch Servo
120°
120° CCPM
O
A
BC D
140°
Elevator Servo
140° CCPM
Aileron Servo
Pitch Servo
3. Press UP or DOWN key to select the mixing rate item, and then press R/+ or
L/- key to set the value of the item.
AIL Mix: This parameter is used to set the mixing rate (percentage) from
aileron to pitch when operating the aileron stick. Values:-100~100. If the value
is negative, it will adjust the pitch operation in the negative direction. If the
value is positive, it will adjust the pitch operation in the positive direction. The
default is 100.
ELE Mix: This parameter is used to set the mixing rate (percentage) from
elevator to aileron and pitch when operating the elevator stick. Values:
-100~100. If the value is negative, it will adjust the aileron and pitch operation
in the negative direction. If the value is positive, it will adjust the aileron and