User Manual DEV 2194
46 Copyright DEV Systemtechnik GmbH 2013-2017
5.5.4.3 .application
5.5.4.3.1 .application.controlMode
OID: .1.3.6.1.4.1.21035.41.2.1.0
Syntax: INTEGER {local (1), remote (2), auto (3)}
Access: read-write OR read-only
Description: The device operation mode (chapter 5.1), possible values:
"1" Local Mode: local operation at the device or
via Web Interface;
"2" Remote Mode: remote operation via SNMP;
"3" Auto Mode: is not supported for this type of device.
Note:
The value "3" (Auto Mode) is not supported for this type of device. The
behavior of the device is not predictable if .controlMode is set to "3".
Via the SNMP setup of the Web Interface (please refer to chapter 5.4.7.2.2)
.controlMode can be set to read-write (default) or to read-only.
The factory setting is "2" (Remote Mode).