5.5.4.4.7 .surveillance.numberOfPowerSupplies
OID: .1.3.6.1.4.1.21035.41.3.7.0
Syntax: Integer32
Access: read-only
Description: The number of power supplies.
This type of device does not support monitoring for the power
supply, thus "0" is returned.
Note:
This value is used to determine the maximum index of the following table:
5.5.4.4.8 .surveillance.powerSupplyTable
The .powerSupplyTable is required for products that support power supply
monitoring, i.e. it is not relevant for this type of device. Therefore and due to the
fact that for .numberOfPowerSupplies (please refer to chapter 5.5.4.4.7) "0" is
returned, the .powerSupplyTable is not available.
5.5.4.4.8.1 .surveillance.powerSupplyTable.powerSupplyEntry.powerSupplyIndex
OID: .1.3.6.1.4.1.21035.41.3.8.1.1.x
Syntax: Integer32 (1..3)
Access: not-accessible
Description: A unique value for each table entry ranging between "1" and the
number of entries (defined by .numberOfPowerSupplies, please
refer to chapter 5.5.4.4.7).
Not applicable for this type of device, since the .powerSupplyTable
is not available.
5.5.4.4.8.2 .surveillance.powerSupplyTable.powerSupplyEntry.powerSupplyStatus
OID: .1.3.6.1.4.1.21035.41.3.8.1.2.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of the related power supply.
Not applicable for this type of device, since the .powerSupplyTable
is not available.
5.5.4.4.9 .surveillance.numberOfFans
OID: .1.3.6.1.4.1.21035.41.3.9.0
Syntax: Integer32
Access: read-only
Description: The number of fans.
This type of device provides no fans, thus "0" is returned.
Note:
This value is used to determine the maximum index of the following table:
5.5.4.4.10 .surveillance.fanTable
The .fanTable is required for products that provide fans, i.e. it is not relevant for
this type of device. Therefore and due to the fact that for .numberOfFans (please
refer to chapter 5.5.4.4.9) "0" is returned, the .fanTable is not available.