5.5.4.3.9.12 .application.portTable.portEntry.poHasGain
OID: .1.3.6.1.4.1.21035.41.2.9.1.12.x
Syntax: INTEGER {yes (1), no (2), (0)}
Access: read-only
Description: The indication whether gain control is provided or not.
For this type of device, "1" (yes) is returned for all ports.
5.5.4.3.9.13 .application.portTable.portEntry.poGain
OID: .1.3.6.1.4.1.21035.41.2.9.1.13.x
Syntax: Integer32
Access: read-write
Description: The gain control value in [dB/10].
"9999" means not available or not present.
Example: "50" ≡ +5.0 dB
Note:
The factory setting is stated in chapter 4.3.1.
5.5.4.3.9.14 .application.portTable.portEntry.poHasTilt
OID: .1.3.6.1.4.1.21035.41.2.9.1.14.x
Syntax: INTEGER {yes (1), no (2), (0)}
Access: read-only
Description: The indication whether slope (or tilt) control is provided or not.
For this type of device, "1" (yes) is returned for all ports.
5.5.4.3.9.15 .application.portTable.portEntry.poTilt
OID: .1.3.6.1.4.1.21035.41.2.9.1.15.x
Syntax: Integer32
Access: read-write
Description: The slope (or tilt) setting in [dB/10].
"9999" means not available or not present.
Example: "20" ≡ +2.0 dB
Note:
The factory setting is stated in chapter 4.3.1.
5.5.4.3.9.16 .application.portTable.portEntry.poCardType
OID: .1.3.6.1.4.1.21035.41.2.9.1.16.x
Syntax: OCTET STRING (SIZE(32))
Access: read-only
Description: The DEV number of the module (here: amplifier) to which the port
belongs to.
"11-0081" (for a DEV 11-0081) is returned for all ports.