User Manual DEV 2194
48 Copyright DEV Systemtechnik GmbH 2013-2017
5.5.4.3.5.3 .application.switchGroupTable.switchGroupEntry.swMainRfStatus
OID: .1.3.6.1.4.1.21035.41.2.5.1.3.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The RF signal status for the main ports of the switch units being
member of the corresponding switch group.
Not applicable for this type of device, since the .switchGroupTable
is not available.
5.5.4.3.5.4 .application.switchGroupTable.switchGroupEntry.swRedundancyRfStatus
OID: .1.3.6.1.4.1.21035.41.2.5.1.4.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The RF signal status for the redundancy ports of the switch units
being member of the corresponding switch group.
Not applicable for this type of device, since the .switchGroupTable
is not available.
5.5.4.3.6 .application.numberOfSwitchUnits
OID: .1.3.6.1.4.1.21035.41.2.6.0
Syntax: Integer32
Access: read-only
Description: The number of switch units within the device.
This type of device does not support switch units, thus "0" is
returned.
Note:
This value is used to determine the maximum index of the following table:
5.5.4.3.7 .application.switchUnitTable
The table is required for products that feature switch units, i.e. it is not relevant for
this type of device.
Therefore and due to the fact that for .numberOfSwitchUnits (please refer to
chapter 5.5.4.3.6) "0" is returned, the .switchUnitTable is not available.
5.5.4.3.7.1 .application.switchUnitTable.switchUnitEntry.swIndex
OID: .1.3.6.1.4.1.21035.41.2.7.1.1.x
Syntax: Integer32 (1..64)
Access: not-accessible
Description: A unique value for each table entry ranging between "1" and the
number of entries (defined by .numberOfSwitchUnits, please refer
to chapter 5.5.4.3.6).
Not applicable for this type of device, since the .switchUnitTable is
not available.