5.5.4.3.9.17 .application.portTable.portEntry.poSlot
OID: .1.3.6.1.4.1.21035.41.2.9.1.17.x
Syntax: OCTET STRING (SIZE(32))
Access: read-only
Description: The "slot location" of the module (here: amplifier) to which the
port belongs to.
"Amp1" is returned for the first amplifier and "Amp2" is returned
for the second amplifier.
5.5.4.3.9.18 .application.portTable.portEntry.poRfSenseStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.18.x
Syntax: INTEGER {(0), ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of the RF level monitoring, possible values:
"0" is not returned for this type of device;
"1" ok: the RF level is above the RF threshold level;
"2" not ok: the RF level is below the RF threshold level;
"3" not applicable: is not returned for this type of device.
5.5.4.3.9.19 .application.portTable.portEntry.poBiasStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.19.x
Syntax: INTEGER {(0), ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of the LNB (bias) current monitoring, possible values:
"0" is not returned for this type of device;
"1" ok: the current is within the defined current monitoring
interval (or LNB power is turned off);
"2" not ok: the current exceeds the defined current monitoring
interval;
"3" not applicable: is not returned for this type of device.
5.5.4.3.9.20 .application.portTable.portEntry.poLightStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.20.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The light detection status.
For this type of device, "3" (notapplicable) is returned for all ports.
5.5.4.3.9.21 .application.portTable.portEntry.poCardStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.21.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The health status of the module (here: amplifier) to which the port
belongs to, possible values:
"1" ok: no errors are reported for the module;
"2" not ok: an error was detected for the module;
"3" not applicable: is not returned for this type of device.