User Manual DEV 2194
Copyright DEV Systemtechnik GmbH 2013-2017 63
5.5.4.4.10.1 .surveillance.fanTable.fanEntry.fanIndex
OID: .1.3.6.1.4.1.21035.41.3.10.1.1.x
Syntax: Integer32 (1..16)
Access: not-accessible
Description: A unique value for each table entry ranging between "1" and the
number of entries (defined by .numberOfFans, please refer to
chapter 5.5.4.4.9). Not applicable for this type of device, since the
.fanTable is not available.
5.5.4.4.10.2 .surveillance.fanTable.fanEntry.fanStatus
OID: .1.3.6.1.4.1.21035.41.3.10.1.2.x
Syntax: INTEGER {ok (1), notok (2)}
Access: read-only
Description: The status of the related fan.
Not applicable for this type of device, since the .fanTable is not
available.
5.5.4.4.11 .surveillance.internalDeviceStatus
OID: .1.3.6.1.4.1.21035.41.3.11.0
Syntax: INTEGER {ok (1), notok (2)}
Access: read-only
Description: The internal device status (e.g. temperature, communication),
possible values:
"1" ok: no internal device errors are reported;
"2" not ok: an internal device error was detected.
5.5.4.4.12 .surveillance.externalDeviceStatus
OID: .1.3.6.1.4.1.21035.41.3.12.0
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of external devices, e.g. of an antenna controller.
There are no external devices available for the DEV 2194, thus
"3" (notapplicable) is returned.
5.5.4.4.13 .surveillance.supportHardwareStatus
OID: .1.3.6.1.4.1.21035.41.3.13.0
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of supporting hardware, e.g. of a digital interface
module. There is no supporting hardware available for the
DEV 2194, thus "3" (notapplicable) is returned.
5.5.4.4.14 .surveillance.errorDescription
OID: .1.3.6.1.4.1.21035.41.3.14.0
Syntax: OCTET STRING (SIZE(1..48))
Access: accessible-for-notify
Description: .errorDescription contains the latest error description string, which
is used for .trapAlarmText; please refer to chapter 5.5.4.1.1.