User Manual DEV 2194
Copyright DEV Systemtechnik GmbH 2013-2017 49
5.5.4.3.7.2 .application.switchUnitTable.switchUnitEntry.swSize
OID: .1.3.6.1.4.1.21035.41.2.7.1.2.x
Syntax: Integer32
Access: read-only
Description: The size of the switch unit.
Not applicable for this type of device, since the .switchUnitTable is
not available.
5.5.4.3.7.3 .application.switchUnitTable.switchUnitEntry.swMembers
OID: .1.3.6.1.4.1.21035.41.2.7.1.3.x
Syntax: OCTET STRING
Access: read-only
Description: A comma separated string that is interpreted as integers, con-
taining the indices of the ports in the .portTable (please refer to
chapter 5.5.4.3.9) being member of the switch unit.
Not applicable for this type of device, since the .switchUnitTable is
not available.
5.5.4.3.7.4 .application.switchUnitTable.switchUnitEntry.swPosition
OID: .1.3.6.1.4.1.21035.41.2.7.1.4.x
Syntax: Integer32
Access: read-write
Description: The switching status of the related switch unit.
Not applicable for this type of device, since the .switchUnitTable is
not available.
5.5.4.3.8 .application.numberOfPorts
OID: .1.3.6.1.4.1.21035.41.2.8.0
Syntax: Integer32 (0..255)
Access: read-only
Description: The number of ports with special properties within the device.
Each amplifier is considered as a single port, thus "2" is returned.
Note:
This value determines the maximum index of the following table:
5.5.4.3.9 .application.portTable
The .portTable describes the special features and settings of each amplifier.
5.5.4.3.9.1 .application.portTable.portEntry.portIndex
OID: .1.3.6.1.4.1.21035.41.2.9.1.1.x
Syntax: Integer32 (1..255)
Access: not-accessible
Description: A unique value for each table entry ranging between "1" and the
number of entries (defined by .numberOfPorts, chapter 5.5.4.3.8).