5.5.4.3.9.8 .application.portTable.portEntry.poBiasOnOff
OID: .1.3.6.1.4.1.21035.41.2.9.1.8.x
Syntax: INTEGER {no (0), on (1), off (2), vertlow (3), horlow (4),
verthigh (5), horhigh (6)}
Access: read-write
Description: The LNB power (or bias) supply state can be read or set,
possible values:
"0" no: is not returned for this type of device;
"1" on: is supported only for some configurations (see below);
"2" off: LNB power is (to be) turned off;
otherwise (see below):
LNB power is (to be) turned on & (to be) set to polarization/band
"3" VL (vertical low: 13 V, 0 Hz),
"4" HL (horizontal low: 18 V, 0 Hz),
"5" VH (vertical high: 13 V, 22 kHz), or
"6" HH (horizontal high: 18 V, 22 kHz).
Note:
The factory setting is "2" (off).
In certain DEV 2194 configurations, .poBiasOnOff supports the value "1" (on)
for the VL mode (13 V, 0 Hz), instead of the polarization/band values "3"…"6".
5.5.4.3.9.9 .application.portTable.portEntry.poBiasCurrent
OID: .1.3.6.1.4.1.21035.41.2.9.1.9.x
Syntax: Integer32
Access: read-only
Description: The measured current in [mA/10].
"9999" means not available or not present.
Example: "1850" ≡ 185.0 mA
5.5.4.3.9.10 .application.portTable.portEntry.poBiasLimitLo
OID: .1.3.6.1.4.1.21035.41.2.9.1.10.x
Syntax: Integer32 (0..3000)
Access: read-write
Description: The lower limit of the current monitoring interval in [mA/10].
"9999" means not available or not present.
Example: "1000" ≡ 100.0 mA
Note:
The factory setting is stated in chapter 4.3.1.
5.5.4.3.9.11 .application.portTable.portEntry.poBiasLimitHi
OID: .1.3.6.1.4.1.21035.41.2.9.1.11.x
Syntax: Integer32 (3000..6000)
Access: read-write
Description: The upper limit of the current monitoring interval in [mA/10].
"9999" means not available or not present.
Example: "2500" ≡ 250.0 mA
Note:
The factory setting is stated in chapter 4.3.1.