42 Pictures for illustrating purposes only
Continued
POWER OFF IF DRAI-
NING : yes or no
ADJUST STEAM BY : ------
----------
CYLINDER SELECT
--------------------
This allows to shut down the contactor(s)
during draining to prevent leakage currents.
This allows to select how the unit reduces its
output : either by evaporation (required for
demineralized water) or by draining.
This allows to select the type of cylinder used.
MAINTENANCE IN-
TERVAL ------- KG
MAINTENANCE FRE-
QUENCY --------- H
FOAM / SCALE CON-
TROL
This allows to adjust the estimated number of
produced steam in kg or of working time
before a visual control be made. If a cylinder
maintenance is to be done, please refer to
the cylinder maintenance pages of this
manual. If not, this parameter can be adjusted
for a higher value (factory default time : 300h).
This parameter allows to adjust the time of the
small drain (0 to 10 sec) that takes place
whenever the humidifier takes in water. This
time can be increased when foam is seen
inside the cylinder (particularly when using
softened waters).
ELECTROVAP MC2 STEAM BATH
Management system
Configuration changing menu
PERFUME FREQUENCY ----
MIN
This allows to adjust how frequent the perfume
injections must be (from 1 to 99 mn).
DISINFECTION
DURATION ---- MIN
This allows to adjust how long the disinfection
injection time must be (from 1 to 99 mn). This
requires the optional disinfection system.
TIME BATH ---- MIN
For the time bath version, this allows to pre-
set the running time up to 8 hours.