43 Pictures for illustrating purposes only
DRAINING AFTER SHUT
DOWN ? ----
This function allows the unit to
automatically drain after a certain
time on halt (factory pre-set).
Home menu
SETTING TEMP °C
WATER 65°C -----
NO
YES
NO
DRAIN AFTER
---- H
YES
This enables or not the function of keeping
water temperature of the cylinder at 65°C
when the unit is stopped. NB : this function
requires that the optional kit be installed.
This allows the time
for the above to be
selected (adjustable
from 24 to 168 h.)
ELECTROVAP MC2 STEAM BATH
Management system
Configuration changing menu
IMPORTANT NOTICE
The units have a factory default maintenance time of 300 hours that suits most
cases. The exact maintenance frequency is variable and depends on water
quality, hours of run and steam demand. New installations should be inspected or
serviced frequently to enable a suitable maintenance routine to be established.
For hard or very hard waters, the use of a cleanable cylinder is recommended.
A cleanable cylinder maintenance guide can be found on the next page. This
should be seen as an help only and not be considered as a binding information
from devatec in any case.
IDENTIFICATION OF
ELMC ---
This allows each unit to be given a reference
number when it is connected to a
communication bus.
DATA SPEED -------
b/s
This allows to synchronize the data speed
with the ELMC communication bus