10. Service Mode Field Service Ver. 1.0 Apr. 2005
100
ineo 161
ineo 210
Adjustment / Setting
J. TROUBLE COUNTER
Purpose/Use To display the count of the number of malfunctions detected according to the malfunc-
tion code.
Setting/
Procedure
C0000: Main Motor malfunction
C0044: ADF Cooling Fan failure (should not be used only for ineo 210)
C0045: Fusing Cooling Fan Motor malfunction
C004E:Power Unit Cooling Fan Motor malfunction
C0070: Toner Replenishing Motor malfunction
C0210: Abnormal image transfer voltage
C0500: Warm-up failure
C0501: Warm-up failure 2 (should not be used only for ineo 210)
C0510: Fusing failure (abnormally low temperature)
C0511: Fusing failure (abnormally low temperature 2) (should not be used only for
ineo 210)
C0520: Fusing failure (abnormally high temperature)
C0521: Fusing failure (abnormally high temperature 2) (should not be used only for ineo
210)
C0650: Faulty Scanner Home Position Sensor
C0B60:Bin Switching Motor malfunction
C0B80:Shift Motor malfunction
C0F32: Faulty ATDC Sensor
C0F33: Improperly adjusted ATDC Sensor
C1038: Engine connection failure
C1200: Faulty ASIC/memory
C1300: Polygon Motor malfunction
C133B:Communication with option error
C133C:Modem fault (should not be used only for ineo 210)
C133D:ROM checksum error
C13F0: Faulty HSYNC
C1468: Faulty Parameter Chip
C14A3:IR fluorescent lamp fault
To clear the count, use “Clear Data” of the Service mode.