Field Service Ver. 1.0 Apr. 2005 6. Other
59
ineo 161
ineo 210
Maintenance
for ineo 210
7. Close the right door, and then use a tester to make sure that the Fusing Unit Interlock
Switch is conducting between 2A and 2B, 3A and 3B.
8. Open the right door, and then use a tester to make sure that the Fusing Unit Interlock
Switch is not conducting between 2A and 2B, 3A and 3B.
NOTE
If there is any abnormality in conducting check, repeat adjustment again from step 4.
6.3.23 Inch/Metric Sensor/1 Assy (3rd area Only)
1. Remove the Rear Cover.
31
2. Remove one screw, unplug one con-
nector, and remove the Inch/Metric
Sensor/1 Assy.
6.3.24 Flickerless Resistor (Only for 200 V area of ineo 161)
1. Remove the Rear Cover.
31
2. Remove the Master Board.
33
3. Remove the harness from one wiring
saddle.
4. Remove one screw, unplug one con-
nector, and remove the Flickerless
Resistor.
4035D141AA
4035D140AA

Table of Contents