10. Service Mode Field Service Ver. 1.0 Apr. 2005
86
ineo 161
ineo 210
Adjustment / Setting
H. FUSER TEMP. Ad (OHP)
<Temperature table for adjusting fusing temperature for OHP film>
For ineo 161
For ineo 210
Purpose/Use To set the fusing temperature when OHP film are used.
✽ When fusing failure occurs
Setting/
Procedure
• The default setting is “0.”
Setting range: -1 to +1
Setting value
Paper width
Mode selected in Service’s Choice
Mode 1 Mode 3
CD Fusing Heater Lamp temperature
1
251 mm or more 180 °C 175 °C
250 mm or less 165 °C 165 °C
0 (default value)
251 mm or more 180 °C 165 °C
250 mm or less 155 °C 155 °C
-1
251 mm or more 170 °C 155 °C
250 mm or less 145 °C 145 °C
Setting value
Mode selected in Service’s Choice
Mode 1 Mode 3
Fusing Heater Lamp temperature (main/sub)
1 175 °C
0 (default value) 165 °C
-1 155 °C