OPERATOR’S MANUAL
GAC® 2100 Grain Analysis Computer (Blue, Gray, Agri Models)
11001-1688-201609
28 CALIBRATE PROCEDURES
6. Press the Next Page key to view the Auto Range screen. The Auto
Range screen displays grain name and calibrations automatically used
to extend the moisture range if the normal maximum and minimum
limits are exceeded. Separate grain calibrations or grains may be
referenced for each limit.
Figure 21
View Calibration Menu Showing Wheat HRW
ENTER/CHANGE CALIBRATION VALUES (2 KEY)
Blue model-This function enters or changes grain calibrations. Grains 1
through 40 are restricted to authorized personnel only. Grains 41 through 64
are considered “unofficial calibrations” and can be accessed by using the
Access Code. Changing calibrations is also possible through proper linking
with a computer (refer to the computer manual). The same security code
restrictions exist. After gaining access, changes to calibrations can be
accomplished (Figure 22).
CALIBRATION MENU
1: VIEW CALIBRATION
2: ENTER/CHANGE CALIBRATION
3: PRINT CALIBRATION LIST
4: OBTAIN CALIBRATION DATA
5: PRINT AUDIT MEMORY DATA
SELECT ITEM NUMBER (NEXT PAGE: STATUS)
SELECT GRAIN TO VIEW
1: CORN 5: SOYBEANS
2: CORN HI MOIST 6: MILO
3: WHEAT HRW 7: BARLEY
4: AMARANTH 8: OATS
PAGE 1 OF 8 <more>
VIEW CALIBRATION
GRAIN: WHEAT HRW RANGE: 06 -20%
ISSUE: 960701
K1: 0433 K4: 2821 K7: 2006
K2: 3577 K5: 2500 K8: 0564
K3: 1368 K6: 2577 K9: 1044
<more>
VIEW CALIBRATION
GRAIN: WHEAT HRW
FACTOR 1: VEHICLE NUMBER
FACTOR 2:
FACTOR 3:
FACTOR 4:
<more>
VIEW CALIBRATION
AUTO RANGE FOR: WHEAT HRW
IF ABOVE MAX MOIST TRY: WHEAT HI MOIST
IF BELOW MIN MOIST TRY: WHEAT LO MOIST