- 11 -
DI-80 USER MANUAL
1.5.1.2 Digital Tare
This function can be used when tare weight is decided in advance. The knowing tare value can be entering by numeric keys.
Note: To enable this function, SPEC 27 bit 2 must set to "1" in advance.
OPERATION KEY DISPLAY
0. 020
T T
1. At Weighing Mode, enter the
tare weight by numeric key
(Ex. 20g)
¼0»
¼T» NET
kg
- 0. 0 2 0
T T
2. Press [T] key to subtract the
tare weight.
¼0»
NET
kg
0. 0 0 0
T
T
3. Press [T] key to clear the tare
weight.
Note 1: After set Digital Tare and then called up a PLU, if tare value is set in PLU File in advance, the PLU Tare value will
override the Digital tare value, if not, the Digital Tare value will remain for the PLU.
Note 2: If you want Digital Tare when Weight loaded on platter, SPEC 38 bit 2 must set to "0" in advance. If not, set to "1".