1.7.2 Call Up PLU by Teraoka Code / ASCII Code
For example: Call up PLU in Counting Mode.
OPERATION KEY DISPLAY
¼0»
NET
kg
A00 0 0
T
T
Pcs
1. At Counting Mode, press [.]
key to enter ASCII Code
entry mode.
Using ASCII Code or
Teraoka Code is depending on
SPEC 14 bit 3 setting, 0:
Teraoka Code & 1: ASCII
Code.
¼T» NET
kg
A03 0 0
A 1 2
T
T
Pcs
2. Enter PLU Code by ASCII
Code (Ex. A12).
Manual or Auto Shift to next
position after enters ASCII
Code or Teraoka Code is
depending on SPEC 06 bit 0
setting.
Refer to Note 1.
¼0»
NET
kg
0. 0 0 0
2. 0000 0
T
Pcs
3. Press [PLU] key (The PLU
data will appear on the
display).
The Commodity Name will
appear for a second on Sub-
Display column.
¼0»
NET
kg
0. 0 0 0
0 0
T
T
Pcs
4. Press [C] key to clear the
PLU and display return to
Counting Mode.
Note 1: Press [+] key to next position and [-] key back to previous position.