- 46 -
DI-80 USER MANUAL
1.17 WEIGHT UNIT SWITCHING
This function is used to change the Weight Unit between kg and lb or oz, g and dwt in Weighing Mode or Counting Mode. Only
in Counting Mode, allow changing the weight unit when memory flag is lighter up. The changing Weight Unit will use for all
PLU until main or display switch is turned OFF. To enable this function, SPEC 12 bit 0 must set to "1" In advance.
For example: Change Weight Unit from kg to lb in Weighing Mode.
OPERATION KEY DISPLAY
NET
kg
2. 0 0 0
T
1. At Weighing Mode, place the
product on platter (Ex. 2kg).
NET
4. 4 1 0
lb
T
2. Change weight unit from kg
to lb, press [UNIT
SWITCH] key.
NET
kg
2. 0 0 0
T
3. Press [UNIT SWITCH] key
again to switch back the
previous weight unit.
Note: Increment conversion
1) dwt Scale
dwt g oz
4) kg Scale
kg lb
1 1 1 1 2
2 2 1 2 5
5 5 1 5 10
10 10 1 10 20
2) g Scale
g oz dwt
5) lb Scale
lb kg
1 1 1 1 1
2 1 2 2 1
5 1 5 5 2
10 1 10 10 5
3) oz Scale
oz dwt g
1 20 20
2 50 50
5 100 100
10 200 200