Initial configuration Configure system settings
IX14 User Guide
56
8. Configure Log options:
n
Heartbeat interval: Enter the minimum time between sending heartbeat status events.
n
Event categories: Open the Event categories and enable/disable the event categories
you want to log.
9. Expand Server list and click to configure an additional syslog server.
10. Select Preserve system logs to keep the current system logs when the device is rebooted.
11. Click Apply to save the configuration and apply the change.
Command line
1. Log into the IX14 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Provide the system information settings:
n
(Optional) Set a name for the device. This name will appear in log messages and at the
command prompt.
(config)> system name 192.168.3.1
(config)>
n
(Optional) Set the contact for the device:
(config)> system contact "Jane User"
(config)>
n
(Optional) Set the location for the device:
(config)> system location "9350 Excelsior Blvd., Suite 700, Hopkins,
MN"
(config)>
n
(Optional) Set the banner for the device. This is displayed when users access terminal
services on the device.
(config)> system banner "Welcome to the Digi IX14."
(config)>