TECHNICAL REFERENCE MANUAL
9.2.8 Temperature measurement (sNt)
Triggers measurement of the temperature inside the sensor.
Command
Command
sNt<trm>
Return successful
gNt+xxxxxxxx<trm>
Return error
gN@Ezzz<trm>
Parameters
N Device ID
xxxxxxxx Temperature in 0.1°C
zzz Error code
9.2.9 Laser ON (sNo)
Switches the laser beam ON for easy adjustment.
Command
Command
sNo<trm>
Return successful
gN?<trm>
Return error
gN@Ezzz<trm>
Parameters
N Device ID
zzz Error code
9.2.10 Laser OFF (sNp)
Switches the laser OFF.
Command
Command
sNp<trm>
Return successful
gN?<trm>
Return error
gN@Ezzz<trm>
Parameters
N Device ID
zzz Error code