EMERGENCY DESCENT SYSTEM
As a precaution against possible power failure, the lift is equipped with a battery operated
emergency descent system.
1. Setup of the system
- 12V 44Ah
- recharger
- hydraulic unit 12 VDC
2. Servicing the battery
- the system incorporates an automatic battery recharger with short circuit and overheat
protection
- charging voltage maintenance 13,8V, charging 14,7V
- rated current 3A
- if necessary, top up distilled water above the battery elements
3. The hydraulic unit comprises:
- pressure relief valve, set value 15 MPa (150 bar)
- check valve
- direct current motor 800W
Start the emergency descent system with the pushbutton (20 on the platform and 5 on the chassis).
The emergency descent system can only be operated when the pushbutton is depressed.
ATTENTION!
Start by retracting the telescope completely, continue by lowering the boom and finally turn the
boom system.
The emergency descent system can also be used for raising the support outriggers to the transport
position
If the emergency descent system does not operate try to warn other personnel present on the site so
that they can make the lift engine or the emergency descent unit operational by, for example,
changing the battery.
Always check the condition of the emergency descent system battery before putting the lift into
operation.