TR11: RESISTOR
Adjustable resistor for movement speed for operation from the chassis panel.
TR12: RESISTOR
Adjusting the lowering speed of the articulated arms.
U1: VOLTAGE METER
When the control voltage is switched on, the voltage meter reading indicates the value of
alternating voltage.
PLATFORM CONTROL CENTRE (UCB), RELAYS
K50: CONTROL RELAY FOR SIGNAL LIGHTS WHICH INDICATE THE STATE OF
LOADING OF THE PLATFORM
The relay is controlled by the closing point of the limit switch RK4.
K51: PLATFORM TURN TO THE LEFT
Controlled by the non-locking lever switch S36.
The control movement is stopped by the inductive end limit switch RK9 of the linear motor.
K52: PLATFORM TURN TO THE RIGHT
Controlled by the non-locking lever switch S36.
The control movement is stopped by the inductive end limit switch RK10 of the linear motor.