DINO 210XT
91
DRIVING DEVICE CONTROL CENTRE (DCB)
S21: SELECTOR SWITCH
DRIVING DEVICE IN OPERATION - NOT IN OPERATION
S22: NON-LOCKING OPERATION SWITCH
DRIVING DEVICE; DRIVE TO THE LEFT - TO THE RIGHT
S23: NON-LOCKING OPERATION SWITCH
DRIVING DEVICE; DRIVE TO THE LEFT - TO THE RIGHT
S24: NON-LOCKING OPERATION SWITCH
DRIVING DEVICE; DRIVE TO THE REAR
S25: NON-LOCKING OPERATION SWITCH
DRIVING DEVICE; DRIVE TO THE FRONT
OTHER MARKINGS
B1: BATTERY 12VDC 44AH
E1: THERMORELAY FOR THE ELECTRIC MOTOR
F11: MAIN BATTERY FUSE 125A
J1: PLUG
M1: ELECTRIC MOTOR 230VAC 1.5kW
M2: EMERGENCY DESCENT MOTOR 12VDC
MAX. OPERATING TIME 10 MIN.
M3: MOTOR FOR PLATFORM TURN
PL: ROTARY ADAPTOR
The electric circuits between the chassis and the turning device go through the electric rotary
adaptor.
SR1: Solenoid for the emergency descent unit
When energized, starts the emergency descent unit M2.
SPV: Mains switch
Disconnects the plus terminal of the battery.
T2: Battery recharger
Charging voltage 13,8VDC 6A.
Charges the battery if the mains supply is connected.
VVK: FAULT CURRENT SWITCH 25A 30 ms.
ÄM1: SOUND SIGNAL