EasyManua.ls Logo

Dino 210XT - Daily Inspection (Start-Up)

Dino 210XT
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DINO 210XT
67
DAILY INSPECTION (START-UP INSPECTION)
To be always performed at a new work site and in the beginning of every working day.
The inspection is performed by the user.
In the inspection attention shall be paid to the following issues:
- establish the load-bearing capacity of the ground at the lifting site (see the table "maximum
permissible ground pressure for different soil materials" on page 21 for guidelines)
- verify the standing stability of the lift
- control the due operation of the position indicator
- test the operation of the emergency stop system both from the platform and the chassis
control panels.
- test the operation of the emergency descent system both from the platform and the chassis
control panels
- test the alarm signal
- check the warning and signal lights
- check the operation and cleanliness of the lights and reflectors
- check the condition of the operating controls and test all work movements
- check the condition of the access routes, the platform gate and the handrails
- check the operation of the load limit switches (refer to the service instructions).
- check the limit switches, which prevent the operation of the boom movements (refer to the
service instructions)
- check the operation of the limit switches, which block the outrigger movements (refer to the
service instructions).
- check the hydraulic system for tightness
- test the brakes
- check the unit visually
- observe the location of the nearby power lines (refer to the safety distances on page 9)