EasyManua.ls Logo

Dino 210XT - Power Pack and Boom Lifting Issues; Telescope Operation Failures

Dino 210XT
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DINO 210XT
76
FAULT REMEDY
8. Power pack does not start
Battery is flat. Recharge the battery.
Mains cable is connected. Disconnect the plug from the mains.
No direct-current supply (12VDC). Mains switch turned off, turn on the switch.
9. Power pack cranks but does not start
Fuel tank is empty. Fill the fuel tank.
Choke is off. Press choke button (cold engine).
Throttle lever in idling position. Increase the engine revolutions.
10. Boom cannot be lifted
Refer to item 4.
Electric valve open.
Remedy as instructed above in conjunction with
the seizure of the electric valve spool.
Lifting of the boom makes the lift turn. Solenoid valve is stuck in turning position.
Wash carefully the spool and the block.
11. Telescope movement does not operate
Refer to item 4.
Check that the solenoid valve of the telescope is
not stuck in the centre (open) position.

Table of Contents