6.2 Adjusting parameters
1 Disconnect batteries if any.
2 Disconnect the mains contact.
3 Press the "Learn button (LRN)" and keep it depressed.
4 Connect the mains contact.
5 Watch the "Error LED" flash 2 times for 3 seconds.
6 Release the "Learn Button" after the 3 seconds (LED is out). The "Error LED" flashes a number of short flashes
that corresponds to the parameter group number (see table). After a short pause the LED will repeat the group
number, and so on.
7 Pushing the "Learn button" once, increases the parameter group number. When the highest parameter group number
is reached it will start with number 1 (default) again.
8 Push the button until you get the requested parameter group.
9 Disconnect the mains contact.
10 Next time the mains is connected, the operator will use the new group of parameters.
Parameter/
Group
1
(default)
2
3
4
5
6
7
8
9
10
OPEN/CLOSE
HOLD OPEN
TIME
15 minutes
Infinite
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
15 minutes
BATTERY mode
(FUTURE USE)
Power Save
Power Save
Convenience
Power Save
Power Save
Power Save
Power Save
Power Save
Power Save
Convenience
KILL mode
Locked
during KILL
Locked
during KILL
Locked during
KILL
Lock follows
program se-
lector during
KILL
Locked during
KILL
Locked
during KILL
Locked
during KILL
Locked
during KILL
Lock follows
program
selector during
KILL
Locked during
KILL
OBSTRUCTION
mode
1)
Door closer
Door closer
Door closer
Door closer
Reverses
when
obstructed
Door closer
Door closer
Door closer
Door closer
Reverses
when
obstructed
DOUBLE
EGRESS
mode
Separate
presence
detection
Separate
presence
detection
Separate
presence
detection
Separate
presence
detection
Separate
presence
detection
Common
presence
detection
Separate
presence
detection
Separate
presence
detection
Separate
presence
detection
Separate
presence
detection
LOCK RETRY
On
On
On
On
On
On
Off
On
On
On
OPEN/CLOSE
im
pulse
In AUTO
mode
In AUTO
mode
In AUTO
mode
In AUTO
mode
In AUTO
mode
In AUTO
mode
In AUTO
mode
In OFF, EXIT
and AUTO
mode
In AUTO
mode
In AUTO
mode
KILL Impulse
Configuration
Normally
Open
Normally
Open
Normally
Open
Normally
Open
Normally
Open
Normally
Open
Normally
Open
Normally
Open
Normally
Closed
Normally
Open
If set to "Reverses when obstructed", the operator re-opens when obstructed, similar to a presence impulse.
As default the operator tries to close two times extra in automatic operation, Off or Exit mode and one time in
manual operation, Off or Exit mode if there is a problem with binding striking plates. This function can be
switched off (see "Lock retry" above).
When changing group of parameters, normally only the master control must be configured
in a double door application. When changing from or to group seven, both MASTER and
SLAVE must be configured.
6.0 ACTIVATION UNITS & ACCESSORIES