Storage
Dock Storage
If the dock is not used immediately, follow the requirements as shown below for temporary
storage:
• Store it in a dry, rainproof, and reproof place with no corrosive materials.
• Protect it from erosion and damage caused by wildlife.
• Make sure to check that the outer packaging of the dock is in good condition regularly. Make
sure to charge the backup battery for at least 6 hours every three months.
• If the dock is removed from storage and not used for a period of time, place it in a water-
resistant bag sealed with adhesive tape and then store it in the original packaging with a
desiccant.
• DO NOT tilt or invert the dock or place items on top of the box when the dock is stored in
the box.
Aircraft Storage
When the dock is powered on and working normally, the air conditioning system can adjust
the environment temperature making the aircraft suitable for storage. If the aircraft is stored
separately, follow the requirements as shown below:
• Keep the aircraft and parts clean and dry and store them in a cool dry place. Recommended
storage temperature: between -25° and 55° C (-13° and 131° F).
• Make sure small parts are stored properly to avoid loss. Small parts, such as cables and
straps are dangerous if swallowed. Keep all parts out of reach of children and animals.
• Remove the battery from the aircraft when stored.
Battery Storage
When the dock is powered on and working normally, the air conditioning system can adjust the
environment temperature making the battery suitable for storage. If the batteries are stored
separately, refer to the Safety Guidelines and follow the instructions on battery storage.
IP Rating
IP Rating of the Dock
1. Under stable laboratory conditions, DJI Dock 2 achieves an IP55 protection rating by IEC
60529 standards when used with DJI Matrice 3D Series aircrafts. The protection rating is not
permanent and may lower over an extended period of time. Maintain the device on a regular
basis.
2. The dock does not achieve an IP55 protection rating in the following circumstances:
• The electrical cabinet door is not rmly closed.
• The mounting screws of the wind speed gauge are not rmly tightened.
• The dock cover is not firmly closed (It is abnormal if dock cover has a gap larger than
20 mm).