XR150/XR350/XR550 User Guide 17Arming and Disarming
Area System Disarming Operation
While the system is armed, you can only enter the premises
through an entry/exit delay door without causing an alarm. After
opening the door, the keypad sounds a prewarn tone to remind you
to disarm the system. You must disarm the system before the entry
delay time expires or an alarm on the door zone occurs.
During the entry delay time, the keypad displays ENTER CODE: and
the name of the zone causing the entry delay. Enter your code to
disarm the system. Only those areas assigned to your code disarms.
Note:The prewarn tone silences as soon as the rst user code
digit key is pressed. If a valid user code is not entered or an
invalidusercodeisenteredwithinveseconds,theprewarn
tone begins sounding again.
Schedules: If you have programmed schedules for your system and
a code is entered outside of a schedule and that code does not have
authorization to disarm outside of schedules, the keypad displays
INVALID TIME. This lets users know that they are attempting to
disarm outside of their authorized time.
All or Selective Disarming: After entering your user code, the
system allows you to disarm either all of the areas to which you
have access or just selected areas. If you choose to disarm all
areas, the system automatically disarms them. If you choose to
disarm selected areas, the area names display on the keypad.
Alarm Display: After disarming, the keypad dis plays any zones
that tripped or any transmission problems that occurred dur ing the
armed period. All burglary zones are then dis armed and any by-
passed zones are automatically reset.
Disarmed Message: The keypad displays ALL SYSTEM OFF after the
system disarms.
Central Sta tion Report: Your system may be pre-programmed at
installation to transmit a system disarming report to the central
sta tion.
Door Access Disarming: Your system may be programmed to allow
area disarming when a card is presented to a door access reader
located outside of the building. Simply present your card to the
reader and after the card code is validated for the appropriate
authority, a door access is granted and your matching areas are
automatically disarmed. See the Easy Entry™ User’s Guide in
Appendix E.
Disarming During an Alarm
1. While the alarm bell or siren sounds, enter your user code to
silence the alarm. The keypad tone silences as soon as the
rstkeyispressed.
For a burglary alarm, the keypad displays
IS THIS A FALSE ALARM? NO YES or CANCEL VERIFY.
This allows you to investigate the alarm prior to disarming
the system. This display remains on the keypad until a
selection is made, the Back Arrow is pressed, or the internal
system bell cutoff timer expires.
2. If a valid alarm has not occurred, select YES or CANCEL to
disarm the system and cancel the alarm.
The keypad next displaysALL SYSTEM OFF to conrm the
system is disarmed.
OR
If the alarm is valid, select NO or VERIFY to send a verify
message to the Central Station. The system will remain
armed.

Table of Contents

Other manuals for DMP Electronics XR150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR150 and is the answer not in the manual?

DMP Electronics XR150 Specifications

General IconGeneral
BrandDMP Electronics
ModelXR150
CategoryControl Panel
LanguageEnglish

Related product manuals