Appendix F XR150/XR350/XR550 User Guide 77
Frequently Asked Questions
This section attempts to answer questions you might have regarding system operation.
Q. If I bypass an exit delay door when I arm the system, will I get an alarm if I come through it later?
A. You will not get an alarm from the door because it is bypassed, but if you happen to walk through a motion detector
space or other armed door inside the premises an alarm activates.
Q. When I arm or disarm my Area system, ALL? NO YES displays. Does this mean all areas in the system?
A. Selecting YES arms or disarms all areas that are authorized for your user code.
Q. How do I create a schedule that starts at 8:00 AM on Monday and ends at 5:00 PM on Friday.
A. In the days of the week display, select MON (Monday). For the OPENING TIME?, enter 0 + 8 + 0 + 0 AM. For the CLOSING
TIME?,attheMON—:AMPMdisplay,selectMON;thisscrollsthroughthedaysoftheweek.Stopatthedayyouwant
the schedule to end. Next, enter 0 + 5 + 0 + 0 PM into the FRI — : AM PM closing time display. Press COMMAND. Press
the Back Arrow key to exit the User Menu.
This sets the opening time to 8:00 AM Monday and the closing time to 5:00 PM Friday. You can substitute any other day
or time in this. What do I do if I want to be in the building past the scheduled closing (arming) time?
A. If your system is programmed for closing check, the keypad emits a steady tone prior to the system arming.
During this tone, press any Select key to display ENTER CODE: . Enter your user code and press COMMAND.
The keypad now displays 2HR 4HR 6HR 8HR. Select the number of hours to extend the schedule. If the system is not
armed by the scheduled closing time, a Late to Close report is sent to the central station. If the schedule is extended, a
Schedule Change report may be sent to the central station.