46 XR150/XR350/XR550 User Guide User Menu
3. The keypad displays SELECT WEEK DAY and SUN MON TUE
WED. Press the COMMAND key to display THU FRI SAT HOL.
4. Enter the Begin and End times for each day of the schedule.
Refer to Adding a Schedule for more information.
5. The keypad goes back to the SUN MON TUE WED display.
Press the Back Arrow key to enter another schedule.
Press the Back Arrow key to exit the User Menu.
Setting Area, Output, and Door Schedules
The Schedules function allows you to assign up to 8 different
schedule numbers to each area, output, and door access relay
connected to your system. The schedule number allows the
opening and closing times for the area and on/off times for outputs
and door access relays
1. Access the User Menu.
2. Press COMMAND until SCHEDULES? displays.
3. After you have accessed the SCHEDULES? menu and the
schedule options, TIMES AREAS DOOR, display, press the
COMMAND key once more and the display changes to OUTPUT
HOLIDAYS. Select AREAS, DOOR, or OUTPUT.
4. The keypad displays ENTER THE AREA/OUTPUT/DOOR
NUMBER:- , enter the area, output, or door number you
want to assign a schedule. Press the COMMAND key.
5. The keypad displays SCHEDULE NO: -. Press any Select
key and enter the schedule number (01 to 99). Press the
COMMAND key.
6. The keypad displays the next schedule number allowing you
to enter additional programming. To exit the user menu
press the Back Arrow key.
Setting Holiday ABC Schedules
Three Holiday Schedules are available. This allows an output,
area, or door to have three different schedules for holidays. For
example, Holiday Schedule A for those holidays when the building
stays closed, Holiday Schedule B for a day that only opens for a
morning, etc. Also, Holiday Schedules can be used to cross multiple
days. These schedules become active and supersede the current
day’s schedule when a Holiday Date occurs. See Setting Holiday
Dates (HOL).
1. After you have accessed the SCHEDULES? menu and the
schedule options, TIMES AREAS DOOR, display, press
the COMMAND key until the display changes to OUTPUT
HOLIDAYS. Press COMMAND once more and the display
changes to FAVORITES.
2. Select HOLIDAY to program holiday schedules.
3. ThekeypaddisplaysHOL:ABC.SelectAtosettherstof
three holiday schedules.
4. The keypad displays A - : AM PM.
Note: After Selecting the schedule, the keypad displays any
current times previously set for that holiday. This feature
allows you to review the programmed times.
5. If times display, the keypad then displays DELETE KEEP.
Select DELETE to enter new times.
6. The keypad then displays BEGIN TIME? This is followed by the
display – : AM PM.
Enter a new time and select AM or PM.
The display changes to END TIME? This is followed by the
display – : AM PM.
Enter a new time.
Enter all schedule times using a 12 hour clock. For example,
to enter 6 AM you would enter 0 + 6 + 0 + 0 select AM. For 11
PM you would enter 1 + 1 + 0 + 0 and select PM.
7. The keypad returns to HOL: A B C allowing you to enter A
B and/or C holiday schedule for the same Output or Door. Go
back to step 3 to add additional holiday schedules.

Table of Contents

Other manuals for DMP Electronics XR150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XR150 and is the answer not in the manual?

DMP Electronics XR150 Specifications

General IconGeneral
BrandDMP Electronics
ModelXR150
CategoryControl Panel
LanguageEnglish

Related product manuals