XTL/XTLC Programming Guide Digital Monitoring Products
7
COMMUNICATION
3.9
SECURECOM400
-
FIRST GPRS APN
First GPRS APN (XTL Only)
Enter the rst APN (Access Point Name). This allows an access point for cellular
communication and is used to connect to a DNS network. The APN may contain two
lines of 16 characters to equal 32 characters. Default is set to SECURECOM400.
3.10
SECURECOM400
-
SECOND GPRS APN
Second GPRS APN (XTL Only)
Enter the second APN (Access Point Name). This works as a backup in case the rst
APN fails. The APN may contain two lines of 16 characters to equal 32 character
Default is set to SECURECOM400.
3.11
RECEIVER 1 PROG
Receiver 1 Programming
Allows you to set the options for the rst receiver the panel attempts to contact
when sending reports. The XTL/XTLC supports communication to two receivers.
3.12
ALARM NO YES
Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error,
and System Recently Armed reports to be sent to this receiver. Default is YES.
3.13
SPV/TRBL NO YES
Supervisory/Trouble Reports
YES enables Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and
Fault reports to be sent to this receiver. Default is YES.
3.14
O/C USER NO YES
Opening/Closing and User Reports
YES enables Opening/Closing, Code Changes, and Bypass reports by user to be sent
to this receiver. Default is NO.
3.15
TEST RPT NO YES
Test Report
Enter YES to enable the Recall Test report to be sent to this receiver.
3.16
FIRST IP ADDR
000.000.000.000
First IP Address
Enter the rst (primary) IP address where the panel sends cell messages. Enter all
12 digits and leave out the periods. For example, enter IP address 192.168.0.250 as
192168000250. The periods display automatically.
The message is sent using rst GPRS APN and the rst IP Address. If no
acknowledgment is received, rst GPRS APN and the second IP address are used,
followed, if needed, by second GPRS APN and rst and second IP addresses,
respectively.
3.17
FIRST IP PORT
2001
First IP Port
Enter the rst IP port number to be used in conjunction with the rst IP Address.
The IP port identies the port used to communicate messages to and from the
panel. The default IP Port setting is 2001.
3.18
SECOND IP ADDR
000.000.000.000
Second IP Address
Enter the second IP address where the panel sends network messages. Enter all 12
digits and leave out the periods. For example, enter IP address 192.168.0.250 as
192168000250. The periods display automatically.
3.19
SECOND IP PORT
2001
Second IP Port
Enter the second IP port number to be used in conjunction with the second IP
address. The IP port identies the port used to communicate messages to and from
the panel. The default IP Port setting is 2001.
3.20
RECEIVER 2 PROG
Receiver 2 Programming
Allows you to set the options for the second receiver the panel attempts to contact
when sending reports. The XTL/XTLC supports communication to two receivers.
If you select YES for any of the Receiver 2 options, you must have at least one IP
address programmed in Receiver 2 programming. Receiver 2 defaults are set to NO.
3.21
ALARM NO YES
Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error,
and System Recently Armed reports to be sent to this receiver. Default is NO.