XTL/XTLC Programming Guide Digital Monitoring Products
11
DEVICE SETUP
Device Setup
5.1
DEVICE SETUP
Device Setup
This section allows you to dene the panel wireless keypad conguration. You can
install and address up to four wireless keypads.
5.2
DEVICE NO:-
Device Number
Enter the device number of the wireless keypad you are programming. The valid
range is 2-5.
Note: Address one is reserved for the XTL/XTLC programming keypad attached
during programming. After you program each option for the rst keypad, repeat
these programming steps for each additional keypad.
5.3 Device Name
This section allows you to dene a 16 character alphanumeric name for the device
number. If no name is entered, *UNUSED* is displayed.
To remove a keypad from the system, delete the device name by pressing any Select
key, then press the COMMAND key. The device name is now displayed as * UNUSED *.
5.4 Wireless
Select YES to use a wireless keypad. Default is YES.
5.5
SERIAL#: XXXXXXXX
Serial Number
Enter the eight-digit serial number found on the wireless keypad.
5.6
SUPRVSN TIME: 240
Supervision Time
Press any top row key to select the supervision time required for the device. Press
COMMAND to accept the default time. Default is 240 minutes.
SELECT MINUTES:
0 60 240
Press the Select key under the required number of minutes. The device must check
in at least once during this time or a missing condition is indicated for that device.
Zero (0) indicates an unsupervised wireless keypad.
Note: When the panel is reset, panel is powered down and powered up, or
programming is complete, the supervision timer restarts for all wireless keypads.
* UNUSED *
WIRELESS? NO YES