XTL/XTLC Programming Guide Digital Monitoring Products
29
ZONE INFORMATION
PLS (Pulse) - The output alternates one second on and one second off.
MOM (Momentary) - The output is turned on only once for one second.
TGL (Toggle) - The output alternates between the on state and off state. Each
button press toggles the output state.
OFF
OFF (Off) - The output is turned off. If programmed, the output was turned on by
some other means such as another button press, a zone action, or a schedule.
Note: When the output is assigned to PN/PN2 or EM/EM2 button action and is
turned on, the output turns off when any area is disarmed.
When the output action is steady, pulse or toggle and the output is turned on, the
output remains on until:
— the output cutoff time expires
— the output is reset from the keypad menu
— toggled off
13.12
ALARM ACTION . . .
Alarm Action
The Alarm Action section allows you to change or conrm the default alarm
characteristics of a zone type.
If you selected the non-24-hour zone type Blank, Night, Day, Exit, Auxiliary 1, or
Auxiliary 2, the Alarm Action programing begins with Disarmed Open.
If you selected the 24-hour zone type Fire, Panic, Emergency, or Supervisory, the
Alarm Action programming begins with Armed Open.
13.13
DISARMED OPEN
Disarmed Open
Denes the action taken by the panel when the zone is opened while the area is
disarmed. There are three actions to dene:
• Message to Transmit
• Output/Favorite Number
• Output Action
You must also make these selections for the Disarmed Short, Armed Open, and
Armed Short zone conditions. Press the COMMAND key to continue.
13.13.1
MSG: TROUBLE
Message To Transmit
You can send two report types to the receiver: Alarm and Trouble. These are
represented by the characters A and T. Press any Select key to display the zone
report options.
A T L -
ALARM - Selecting A allows an alarm report to be sent to the receiver and the
wireless siren output to activate according to zone type. See the Bell Action section.
The zone name appears in the panel’s alarmed zones status lists.
TROUBLE - Selecting T allows a trouble report to be sent to the receiver and the
zone name to appear in the panel’s alarmed zones status lists.
LOCAL - When you select L, an alarm report is NOT sent to the receiver. The bell
output still activates according to zone type and the zone name appears in the
panel’s alarmed zones status lists.
– (dash) - When you select – , reports are NOT sent to the receiver. The wireless
siren output does not activate and there is no display in the panel’s alarmed zones
status list. Only the programmed Output Number activates.
12.13.2
OUTPUT NO: 0
Output Number
You can specify any of the outputs/Favorites on the XTL/XTLC to be activated by
a zone condition. The output/Favorite can be activated regardless of the report to
transmit or whether or not the zone is programmed as local. An output activated by
a non-24-hour armed zone is turned off when the zone’s area is disarmed by a user.
To enter an Output Number, press any Select key followed by the output number
31-34, 41-44, or F01-F20. Press the COMMAND key.
13.13.3
ACTION:
NO YES
Output Action
Entering an Output Number displays this prompt that allows you to assign an output
action. A description of the available output actions is given below:
STD PLS MOM FOLW
STEADY - The output is turned on and remains on until the area is disarmed, an