XTL/XTLC Programming Guide Digital Monitoring Products
13
SYSTEM REPORTS
System Reports
7.1
SYSTEM REPORTS
System Reports
This function allows you to select the reports the XTL/XTLC sends to the receiver.
7.2
O/C RPTS NO
NO YES
Opening/Closing Reports
NO - No Opening/Closing Reports are sent.
YES - Sends Opening/Closing Reports for each programmed area.
7.3
ABORT NO YES
Abort Reports
YES allows the panel to send an Alarm Abort Report to the receiver any time an area
is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff
Time has not expired. See the Bell Cutoff section. The area must be disarmed and
no zones that were in alarm can still be armed.
YES also allows a Bell Silenced Report to be sent if the alarm bell is silenced with a
valid user code during an alarm. Default is NO.
Note: Alarm Cancel or Verify Reports are sent if the alarm is canceled or veried
after being sent to the alarm receiver, if the Bell Cutoff timer has not expired. The
Abort Reports option does not affect Cancel or Verify reports.
The panel will not send Abort reports for Fire zones, or Supervisory-type zones.
7.4
RESTORAL YES
NO YES DISARM
Zone Restoral Reports
This option allows you to specify whether the panel sends zone restoral reports and
when they will be sent.
NO - Restoral reports are not sent by the panel.
YES - The panel always sends zone restoral reports at the time the zone restores
from an alarm or trouble condition.
DISARM - The panel sends zone restoral reports when a zone that has restored from
an alarm or trouble is disarmed. Twenty-four hour zones send restorals immediately.
7.5
BYPASS NO YES
Bypass Reports
YES allows the panel to send all zone bypass, reset, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user
number of the individual bypassing the zone.
7.6
CODE CHG NO YES
Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the
receiver. The code change report includes the user number added or deleted and
the user number of the individual making the change.
7.7
AMBUSH NO YES
Ambush
YES allows an ambush report to be sent any time user code number one is entered
at a keypad. Selecting NO disables the ambush report and allows user code number
one to operate the same as all other codes.
7.8
LATE TO OPEN
Late To Open
Enter 1-240 as the number of minutes to elapse that the system may remain armed
after the opening time of a schedule without sending a Late To Open message. If
the system continues to be armed after the Late to Open minutes expire, a Late To
Open message is sent to the central station. Default is 0, which disables the Late To
Open option.
7.9
EARLY TO CLOSE
Early To Close
Enter 1-240 as the number of minutes that the system can be armed prior to the
scheduled closing time. If the system is armed prior to the Early to Close minutes,
an Early To Close message is sent to the central station. Default is 0, which disables
the Early to Close option.