Digital Monitoring Products XTL/XTLC Programming Guide
32
Stop
14.1
STOP
Stop
At the STOP prompt, pressing any Select key allows you to exit the programmer
function of the XTL/XTLC panel. When selected, the panel performs an internal
reset and exits the programmer. The Stop function causes the following conditions
to occur:
All 1100 Series DMP Wireless transmitters are reset to NORMAL
• The panel’s Status List is CLEARED
During the Stop function, all keypad displays are momentarily disabled for two
seconds. Afterwards, the programming function is terminated and the keypads
return to the Status List display.
SET LOCKOUT CODE
Set Lockout Code
15.1
SET LOCKOUT CODE
Set Lockout Code
Pressing COMMAND at the Stop prompt displays SET LOCKOUT CODE. This feature
allows you to program a special code that will then be required to gain access to
the panel’s internal Programmer through the keypad.
Changing the Lockout Code
You can change this code at any time to any combination of numbers from 1 to 5
digits long (1 to 65535). Do not use leading zeros for the lockout code.
1. Press any Select key. The display changes to ENTER CODE: -.
2. Enter a 1- to 5-digit code (do not enter a number higher than 65535). Press
COMMAND.
3. Enter the new Lockout Code again. Press COMMAND. The keypad display
changes to CODE CHANGED.
Once you have changed the code, it is important that you write it down and store
it in a safe place. Lost lockout codes require the panel to be sent back into DMP for
repair. You may cancel a Lockout Code by entering 00000 at the Set Lockout Code
command prompt.
Lockout Code restriction
Do not set a Lockout Code higher than 65535.
STOP

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XTLC and is the answer not in the manual?

DMP Electronics XTLC Specifications

General IconGeneral
BrandDMP Electronics
ModelXTLC
CategoryControl Panel
LanguageEnglish

Related product manuals