CT100 inverter Function parameters
72
Function
code
Name
Detailed instruction of
parameters
Min. unit
Default
value
Modify
No.
F06.28
HDI lower limit
frequency
0.00kHzF06.30
0.01kHz
0.00kHz
F06.29
Corresponding
setting of HDI
lower limit
frequency
-100.0%100.0%
0.1%
0.0%
F06.30
HDI upper limit
frequency
F06.2850.00kHz
0.01kHz
50.00kHz
F06.31
Corresponding
setting of HDI
upper limit
frequency
-100.0%100.0%
0.1%
100.0%
F06.32
HDI frequency
input
filter time
0.00s10.00s
0.01s
0.10s
F07 Group Output terminals
F07.00
HDO output
mode
0: pulse output
1: open collector output
1
0
F07.01
HDO open
collector output
0: no output
1: running
2: fault output
3: frequency level detection
FDT output
4: forward running
5: reverse running
6: ready to run
7: frequency arrival
8: zero speed running
9: upper limit frequency
arrival
10: lower limit frequency
arrival
11: overload pre-alarm
12: set count value arrival
1
1
F07.02
DO collector
output
1
4
F07.03
Relay T1 output
1
5
F07.04
Relay T2 output
1
0