CT100 inverter Function parameters
75
Function
code
Name
Detailed instruction of
parameters
Min. unit
Default
value
Modify
No.
F08.00
Motor overload
protection
0: No protection
1: ordinary motor (with low
speed compensation)
2: variable frequency motor
(without low speed
compensation)
1
2
F08.01
Motor overload
protection factor
20.0%120.0%
0.1%
100.0%
F08.02
Motor overload
warning point
10.0200.0% (relative to the
rated current of the inverter)
0.1%
G type
150.0%
P type
120.0%
F08.03
Motor overload
warning
detection time
0.060.0s
0.1s
0.1s
F08.04
Overload
warning
actuation
selection
0: no detection
1: overload warning is valid in
running, continue to run
2: overload warning is valid in
running, alarm (E.oL3) and
stop
3: overload warning is valid in
constant speed running,
continue to run after
detection
4: overload warning is valid in
constant speed running,
alarm (E.oL3) and stop after
detection
1
1
F08.05
Overvoltage
stall selection
0: disabled
1: enabled
1
1
F08.06
Overvoltage
stall protection
voltage
110150%
1%
135%