16 HAC Standard fixing - 02/2018dormakaba c-lever pro
3.4 Technical data
Data transfer
RFID
TouchGo c-lever E310 ver-
sion:
RCID and RFID
TouchGo c-lever E110 ver-
sion:
RCID (no RFID)
Body
Lever handle Stainless steel
Frame Zinc
Cover Stainless steel
Antenna cover Synthetic material
Power supply
Batteries 1.5V, AA lithium
Ambient conditions
1
Protection type External fitting IP55
Internal fitting IP40
Temperature External fitting -25°C – +70°C
Internal fitting -0°C – +50°C
The temperature range can
be reduced based on the spe-
cification of the batteries
used.
Humidity 0%–95% rH, non-condensing
Climate Unsuitable for use in highly
corrosive atmospheres
(chlorine, ammonia).
Rooms Not to be used in environ-
ments where there is a risk
of explosion.
Media technology
RFID LEGIC advant
prime
MIFARE DESFire
classic
TouchGo c-lever version: RCID
Standards
Fire protection DIN 18273 tested in accord-
ance with EN 1634-1
EI
2
90-C
DO 20.31
EN179 According to test certificate:
1
0432 - BPR - 0061 (Kaba);
1
0432 - BPR - 0003 (BKS);
0432 - BPR - 0005 (Dorma)
Protection class EN 1906 class 0
1
EN1906 class 2 for ES1 - TBD