Service Technical Manual
62 HAC Standard fixing - 02/2018dormakaba c-lever pro
8.6.2 Reset using tweezers
NOTICE
Danger of damage to electronic components from electrostatic discharge.
If electronic printed circuit boards and components are handled incorrectly, damage may oc-
cur which leads to their complete breakdown or sporadic faults.
When installing and repairing the product, the general ESD protective measures are to be
observed.
Requirements
The multitool is available
Electrically conductive tweezers are available.
The batteries are inserted
Procedure
NOTICE
Damage to the union nut
When loosening the union nut, make sure it does not touch the threaded pin.
Using the multitool, loosen the union nut from the internal fitting (>360°).
>360°
With locking cylinder: If necessary, loosen the forend locking stud.
Push the cover out of the groove (1), pull it forwards slightly (2) and turn (3).