Section 5: Programming
7 Burglary Not Verified
When using Cross Zoning, this reporting code is sent if the cross zone timer is initiated by the first cross zone alarm, but is
not verified by a second alarm before the timer expires.
8 Alarm Cancel
Sent when a valid access code is entered during the communications cancel window. The central station acknowledges can-
cellation by providing a keypad ringback.
[002] Miscellaneous Alarm 2
1 Holdup Verified
Sent when the configured Holdup verified conditions have been met.
NA
Note: Not for use with UL/ULC listed installations.
[011] Priority Alarms 1
The reporting codes in this section are sent to the Alarm & Restore call direction group and apply to all system keypads.
1/2 Keypad Fire Alarm-[F] Key Alarm/Restore
Sent when [F] Key alarms/restores occur.
3/4 Keypad Medical Alarm-[M] Key Alarm/Restore
Sent when [M] Key alarms/restores occur. The keypad beeps 10 times when the medical alarm is successfully com-
municated to the alarm monitoring station.
5/6 Keypad Panic Alarm-[P] Key Alarm/Restore
Sent when [P] Key alarms/restores occur.
7/8 Auxiliary Input Alarm/ Restore
Sent when an alarm condition occurs/ is restored on PGM 2 (if configured as an input).
[021] Fire Alarms 1
3/4 PGM 2 2-Wire Alarm/Restore
When PGM 2 is programmed as a 2-wire smoke alarm, this reporting code is sent when an alarm condition is detected and
when it is restored.
[101] Tamper Events
3/4 Module Tamper/Restore
This reporting code is transmitted when a system module enters a tamper alarm state and uses the System Tamper Alarm
and Tamper Restore call direction.
5 Keypad Lockout
Sent when a number of invalid access codes have been entered at a system keypad.
This reporting code is sent to the system Tamper Alarm & Tamper Restore call direction group.
7 Remote Lockout
Sent when a number of invalid access codes have been entered through DLS or Integration. This reporting code is sent to
the system Tamper Alarm & Tamper Restore call direction group.
[201] Open/Close Events 1
1/2 User Closing/Opening
This reporting code is transmitted when a user arms/disarms a partition and uses the Opening and Closing call direction.
5/6 Special Closing/Opening
This reporting code is transmitted when a partition is closed/opened using quick arm ([*][0]), downloading, or Stay or Away
function keys without an access code. The Opening and Closing call direction group is used for this reporting code.
7/8 Keyswitch Opening/Closing
This reporting code is transmitted when a keyswitch zone is used to arm or disarm the system.
[202] Open/Close Events 2
1 Automatic Closing
This reporting code is transmitted when a partition is automatically armed or schedule armed and uses the Opening call dir-
ection group.
- 101 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes