Section 5: Programming
[405] PSTN Double Call Timer
Use this section to program the amount of time that can elapse between the first and second call when using Double Call
downloading. Valid entries are 001 to 255 (seconds).
[406] PSTN Number of Rings to Answer On
The value in this section determines how many rings are required in order to establish a DLS connection. Default value is
000 rings. Valid entries are [000]-[020].
Note: If Double-Call option and Number of Rings to Answer are enabled, either one will work depending on how the
installer calls the alarm system.
[407] SA Access Code
This 6-digit hexadecimal code allows the alarm system to confirm the identity of the downloading computer.
If the code does not match the computer, the alarm system does not allow uploading/downloading.
Programming the access code as FFFFFF disables SA access.
Once an SA connection is established, multiple attempts to input the correct downloading access code (programmed in
[012]) is allowed.
The operator is allowed three attempts to enter the correct access code. If these attempts are unsuccessful, the alarm system
disconnects and a new attempt must be made.
If cellular or IP paths are used for the SA connection, up to five unsuccessful attempts causes a 1-hour SA lockout (See
"Remote Lockout DLS" on page 85).
[410] Automatic DLS/SA Options
[001] Auto DLS Options
1 Periodic DLS
ON: Upload/download commands programmed in advance (batch files) are periodically downloaded to the DLS computer.
See below to program the times and days when this occurs.
Note: The computer must be waiting for a call in order for this feature to work.
OFF: The alarm system does not periodically call the downloading computer.
3 DLS on Event Buffer %75 Full
ON: The alarm system automatically calls the downloading computer with DLS when the Event Buffer 75% full event occurs.
This option is independent of the actual transmission of the Event Buffer 75% full event (the event does not need to be trans-
mitted for the panel to perform the automatic upload).
The panel first communicates the Event Buffer 75% full event (if enabled) using either PSTN or IP and then performs the auto-
matic download.
OFF: The alarm system does not automatically call the downloading computer when the Event Buffer 75% full event occurs.
8 DLS on Programming Change
ON: When the panel returns to the "Ready to Arm" screen after a programming change, 15 minutes later the alarm system
automatically calls the downloading computer.
OFF: The alarm system does not automatically call the downloading computer when the system programming changes.
[002] Periodic DLS Days
This section is used to program the number of days between periodic DLS downloads. Valid entries are from 001 to 255
days.
[003] Periodic DLS Time
This section is used to program the time of day periodic DLS download takes place. Time is in 24-hour format and the default
is 00:00 (midnight).
[007] Delay Call Window
This section is used to define a user call-up window. Users can only initiate a downloading session during this window.
When a value is entered in this section, the setting in Periodic DLS Time (see the option above) is overridden. When 00:00 is
entered in this field, the alarm system initiates a DLS call at the time programmed in Periodic DLS Time. Start and end times
must be defined using 24-hour format (e.g., 13:30) and cannot span a day (e.g., start time of 23:00 and an end time of 01:00).
- 114 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC Neo and is the answer not in the manual?

DSC Neo Specifications

General IconGeneral
ModelDSC Neo
CategorySecurity System
PartitionsUp to 8
TypeHybrid Security System
ZonesUp to 128 zones
CommunicationCellular, IP
CompatibilityPowerG wireless sensors
Remote AccessYes, via app
PGMs4
Wireless RangeUp to 2 km with PowerG
Event Buffer1000 events
Wireless Frequency433 MHz, 868 MHz
Power Supply16.5VAC, 40VA
Battery BackupYes, 12VDC 7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Event LogYes